Kelvinator Air Conditioner Troubleshooting

Air conditioning of a good brand can save you time and money on its repair. But breakdowns are inevitable no matter what brand your air conditioner is. Therefore, it is necessary to have a full manual at hand. In the issue of Kelvinator air conditioner troubleshooting, you will need the tables below.

Kelvinator KSV26CRC Air Conditioner Troubleshooting

ProblemCause
The unit does not operateThe unit does not operate if it is turned on immediately after it is turned off. This is to protect the unit. You should wait about 3 minutes.
Odours are emitted• Some odours may be emitted from the indoor unit. This is the result of room smells (such as furniture, tobacco, etc.) which have been taken into the air conditioner.
• Consult authorised service centre for cleaning if the odours persist.
"Water flowing" noiseThe swishing noise like water flowing is the refrigerant flowing inside the unit.
Mist is emitted in COOL modeDuring cooling operation, a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity.
After a period of time, the mist will disappear as the decrease of room temperature and humidity decreases.
Cracking noiseThis is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
The unit can not be started up• Is the power cut off?
• Is the power plug loose? (if applicable)
• Is the circuit protection device tripped off?
• Is voltage higher or lower? (Tested by professionals)
• Is the TIMER correctly used?
Cooling/Heating effect is poor• Is temperature setting appropriate?
• Is the inlet or outlet blocked?
• Is the filter dirty?
• Is the window or the door open?
• Is low fan speed set?
• Are there heat sources in the room?
Remote control does not transmit signals• Check if there is magnetic or electrical interference near the unit that may affecting operation of the remote control. In this case, pull the plug out and reinsert it.
• Is the remote control within its operating range or obstructed? Check the condition of the batteries and replace them if necessary.
• Check if the remote control is damaged.
Water leakage of outdoor unit• During cooling operation, water condensates around the pipes and connection joints.
• During defrosting operation, thawed water flows out.
• During heating operation, water on the heat exchanger drips out.
Noise from indoor unit.• The noise emitted when the fan or compressor relay is switched on or off.
• When the defrosting operation is started or stopped, there is a sound of refrigerant flowing in the reverse direction.
Indoor unit can not blow air• In HEAT mode, when the temperature of indoor heat exchanger is very low, air flow is stopped in order to prevent cold air. (within 2 minutes)
• In HEAT mode, when the outdoor temperature is low or humidity is high, frost will be formed on the outdoor heat exchanger. The unit will defrost automatically and indoor unitwill stop blowing air for 3-12 minutes.
• During defrosting operation, water or vapour may be emitted.
• In DRY mode, the indoor fan will stop blowing air for 3-12 minutes in order to avoid condensing water being vaporised again.
Moisture on air outlet• If the unit operates at high humidity for a long time, moisture will be generated on the air outlet grill and then drip off.
H1: DefrostingIt is normal. The unit is in defrosting mode and heating will recommence soon.
E3: Low pressure warningYour air conditioner has lost refrigerant. Contact your installer to check for potential leaks.

Kelvinator KWH20HRB Air Conditioner Troubleshooting

ProblemPossible CausesWhat To Do M
Air conditioner does not start■ The air conditioner is unplugged.• Make sure the air conditioner plug is pushed completely into the outlet and switched on.
■ The fuse is blown/circuit breaker is tripped.• Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
■ Power failure.• If power failure occurs, switch off and disconnect /unplug the power cord. When power is restored, reconnect (plug in) the power cord, switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner does not cool as it should■ Airflow is restricted.• Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
■ The air filter is dirty.• Clean the filter at least every 2 weeks.
■ The room may have been hot.• When the air conditioner is first turned on you need to allow time for the room to cool down.
■ Cold air is escaping.• Check for open furnace floor registers and cold air returns.
■ Cooling coils have iced up.• Set the air conditioner's vent to the closed position.
Air conditioner freezing up■ Ice blocks the air flow and stops the air conditioner from cooling the room.• Set the fan at MED or HIGH until the ice melts.

Kelvinator KSV26CRE Air Conditioner Troubleshooting

ProblemPossible CausesDiscriminating Method (Air conditioner Status)Troubleshooting
Air Conditioner Can't be Started UpNo power supply, or poor connection for power plugAfter energization, operation indicator isn’t bright and the buzzer can't give out soundConfirm whether it's due to power failure. If yes, wait for power recovery. If not, check power supply circuit and make sure the power plug is connected well.
Wrong wire connection between indoor unit and outdoor unit, or poor connection for wiring terminalsUnder normal power supply circumstances, operation indicator isn't bright after energizationCheck the circuit according to circuit diagram and connect wires correctly. Make sure all wiring terminals are connected firmly
Electric leakage for air conditionerAfter energization, room circuit breaker trips off at onceMake sure the air conditioner is grounded reliably
Make sure wires of air conditioner is connected correctly
Check the wiring inside air conditioner. Check whether the insulation layer of power cord is damaged; if yes, place the power cord.
Model selection for air switch is improperAfter energization, air switch trips offSelect proper air switch
Malfunction of remote controllerAfter energization, operation indicator is bright, while no display on remote controller or buttons nave no action.Replace batteries for remote controller Repair or replace remote controller
Poor Cooling (Heating) for Air ConditionerSet temperature is improperObserve the set temperature on remote controllerAdjust the set temperature
Rotation speed of the IDU fan notor is set too lowSmall wind blowSet the fan speed at high or medium
Filter of indoor unit is blockedCheck the filter to see it's blockedClean the filter
Installation position for indoor unit and outdoor unit is improperCheck whether the installation position is proper according to installation requirement for air conditionerAdjust the installation position, and install the rainproof and sun proof for outdoor unit
Refrigerant is leakingDischarged air temperature during cooling is higher than normal discharged wind temperature; Discharged air temperature during heating is lower than normal discharged wind temperature; Unit's pressure is much lower than regulated r angeFind out the leakage causes and deal with it. Add refrigerant.
Malfunction of 4-way valveBlow cold wind during heatingReplace the 4-way valve
Malfunction of capillaryDischarged air temperature during cooling is higher than normal discharged wind temperature; Discharged air temperature during heating is ower than normal discharged wind temperature; Unit't pressure is much lower than regulated r ange. If refrigerant isn’t leaking, part of capillary s blockedReplace the capillary
Flow volume of valve is insufficientThe pressure of valves is much lower than that stated in the specificationOpen the valve completely
Malfunction of horizontal louverHorizontal louver can’t swing
Malfunction of the IDU fan motorThe IDU fan motor can't operate
Malfunction of the ODU fan motorThe ODU fan motor can't operate
Malfunction of compressorCompressor can’t operate
ODU fan Motor Can't OperateWrong wire connection, or poor connectionCheck the wiring status according to circuit diagramConnect wires according to wiring diagram to make sure all wiring terminals are connected firmly
Capacity of the ODU fan motor is damagedMeasure the capacity of fan capacitor with an universal meter and find that the capacity is out of the deviation range indicated on the nameplate of fan capacitor.Replace the capacity of fan
Power voltage is a little low or nighUse universal meter to measure the power supply voltage. The voltage is a little high or lowSuggest to equip with voltage regulator
Motor of outdoor unit is damagedWhen unit is on, cooling/heating performance s bad and ODU compressor generates a lot of noise and heat.Change compressor oil and refrigerant. If no better, replace the compressor with a new one
Compressor Can't OperateWrong wire connection, or poor connectionCheck the wiring status according to circuit diagramConnect wires according to wiring diagram to make sure all wiring terminals are connected firmly
Capacity of compressor is damagedMeasure the capacity of fan capacitor with an universal meter and find that the capacity is out ol the deviation range indicated on the nameplate of fan capacitor.Replace the compressor capacitor
Power voltage is a little low or nighUse universal meter to measure the power supply voltage. The voltage is a little high or lowSuggest to equip with voltage regulator
Coil of compressor is burnt outUse universal meter to measure the resistance between compressor terminals and it's 0Repair or replace compressor
Cylinder of compressor is blockedCompressor can't operate
Air Conditioner is LeakingDrain pipe is blockedWater leaking from indoor unitEliminate the foreign objects inside the drain pipe
Drain pipe is brokenWater leaking from drain pipeReplace drain pipe
Wrapping is not tightWater leaking from the pipe connection place of indoor unitWrap it again and bundle it tightly
Abnormal Sound and VibrationWhen turn on or turn off the unit, the panel and other parts will expand and there's abnormal soundThere's the sound of -PAPA"Normal phenomenon. Abnormal sound will disappear after a few minutes.
When turn on or turn off the unit, there's abnormal sound due to flow of refrigerant inside air conditionerWater-running sound can be heard
Foreign objects inside the indoor unit or there're parts touching together inside the indoor unitThere's abnormal sound from indoor unitRemove foreign objects. Adjust all parts' position of indoor unit, tighten screws and stick damping plaster between connected parts
Foreign objects inside the outdoor unit or there're parts touching together inside the outdoor unitThere's abnormal sound from outdoor unitRemove foreign objects. Adjust all parts' position of outdoor unit, tighten screws and stick damping plaster between connected parts

Kelvinator CRE287PM Air Conditioner Troubleshooting

ProblemCause
The unit does not operateThe unit does not operate if it is turned on immediately after it is turned off. This is to protect the unit compressor. Please wait for about 3 minutes before turning the unit on again.
Odours are emittedSome odours may be emitted from the indoor unit. This is the result of room smells (such as furniture, tobacco, etc) which have been taken into the unit.
Consult your authorised service centre for cleaning if the odours persist.
"Water flowing" noiseThe swishing noise like water flowing is the refrigerant flowing inside the unit.
Mist is emitted in COOL modeDuring cooling operation, a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity. After a period of time, the mist will disappear as the room temperature and humidity decrease.
Cracking noiseThis is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
The unit cannot be started up• Is the power cut off?
• Is the power plug loose?
• Is the circuit protection device tripped off?
• Is voltage higher or lower? (tested by professionals)
• Is the TIMER correctly used?
• Are the batteries exhausted?
Cooling/Heating effect is poor• Is the temperature setting appropriate?
• Is the air inlet/outlet blocked?
• Is the filter dirty?
• Is the door or window open?
• Is low fan speed set?
• Are there heat sources in the room?
Water leakage of indoor unit• The humidity is high.
• Condensing water overflows.
• Drain hose is loose or obstructed.
Water leakage of outdoor unit• During cooling operation, water condenses around the pipes and connection joints.
• During defrosting operation, thawed water flows out.
• During heating operation, water on the heat exchanger drips out.
Noise from indoor unit• The noise emitted when the fan or compressor relay is switched on or off.
• When the defrosting operation is started or stopped, there is a sound of refrigerant flowing in the reverse direction.
Indoor unit cannot blow air• In HEAT mode, when the temperature of indoor heat exchanger is very low, airflow is stopped in order to prevent cold air (within 2 minutes).
• In HEAT mode, when the outdoor temperature is low or humidity is high, frost will be formed on the outdoor and the indoor heat exchanger. The unit will defrost automatically and indoor unit will stop blowing air for 2-3 minutes.
• During defrosting operation, water or vapour may be emitted.
• In DEHUMIDIFY mode, the indoor fan will stop blowing air for 3 to 12 minutes in order to avoid condensing water being vapourised again.
Moisture on the air outletIf the unit operates at high humidity for a long time, moisture may be generated on the air outlet grill and then drip off.
H1 code: defrostingThis is normal. The unit is in defrosting operation and heating will recommence soon.

Kelvinator KSV70HRE Air Conditioner Troubleshooting

ProblemCauseSolution
Air Conditioning will not operate• Power switch is released.■Switch on the power.
• Power supply failure.■Wait for power to be restored.
•The fuse is burnt.■Replace the fuse.
•It doesn't reach the set time for start up.■Wait or eliminate the original setting.
Unit Doesn't Start When Pressing On/off Button•Water full indicator flashing, drain tank is full.■Dump the water in the drain tank.
•Room temperature is lower than the set temperature.■Reset the temperature.
Not cooling•Mistakes in temperature setting.■Set a proper temperature, sec the methods of application.
•The air filter is blocked by dust.■Clean the air filter.
•The air inlet or outlet of machinc is blocked.■Remove the obstruction.
•Unit recently turned on in hot room.■Allow additional time to remove stored heat from walls ,ceiling, floor and furniture.
•The doors or windows are open.■Close the doors and windows.
Noise or vibration•The ground is not level.■Place the unit on a flat surface.

Kelvinator KSV25CRG Air Conditioner Troubleshooting

SymptomCause
Operation is delayed after restartTo prevent blowout of the fuse, the compressor will not operate while the protection circuit is working for about 3 minutes after sudden OFF/ON operation of the power supply, this is normal operation and designed to protect the compressor.
Fan speed changes from off, to very slow and then normalAutomatically happens in heating mode :
• prevents cold air blowing onto occupants when the heating operation is start,
• perform automatic defrosting operation,
• perform low temperature heating operation
Heating operation stops suddenly and defrost-light blinksIn HEAT mode, the indoor unit temporarily stops for maximum of 10 minutes to perform the automatic defrosting operation.
Mist coming out of the indoor unitIn COOL mode, a mist generated by condensation formed with sudden cooling process may be emitted.
Mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting
Low volume sounds are emitted by the air conditionerHissing sound - during operation or immediately after stopping the air conditioner, refrigerant flowing sound may be head.
Squeaking sound- normal expansion and contraction of plastic and metal parts caused by temperature change during the operation.
Rushing air- when louver resets its position.
Dust discharges from the unitMay occur when air conditioner is used for the first time or has not been used for a long time.
Emits a peculiar odourVarious smells generated from interior textile, furniture, or cigarette smoke absorbed into the air conditioner may be emitted. If not the case call an authorised service contractor.
Changes to fan only while cooling or heating modeRoom temperature reaches the temperature setting of the remote control. If not the case call your suitable contractor.
Operation is erratic, unpredictable or unresponsiveInterference from cell phone towers and remote boosters may cause the unit to malfunction
Disconnect the power and then re-connect.
Press the ON/OFF button on the remote controller to restart operation.